User Manual Honeywell T8775A1009/U The Digital Round® Non-Programmable Thermostat

CAUTION Electrical Shock or Equipment Damage Hazard. Can shock individuals or short equipment circuitry. Disconnect power supply before installation.

Location

Install the thermostat about 5 ft (1.5m) above the floor in an area with good air circulation at average temperature. Do not install the thermostat where it can be affected by:

Mounting Wallplate to Wall

Wiring

CUSTOMIZE THERMOSTAT

Setting Fuel Switch (T8775C only)

DIP Switch

Set Heat Cycle Rate

Mounting Thermostat to Wallplate

OPERATION

Setting SYSTEM and FAN Switches (T8775C only)

SYSTEM Switch

FAN Switch

CHECKOUT

NOTE: Temperature setpoint range is 40°F to 90°F (4°C to 32°C) in heating and 45°F to 99°F (7°C to 37°C) in cooling.

Heating

  1. Slide the SYSTEM switch to Heat and the FAN switch to Auto (T8775C only).
  2. Raise the temperature setpoint several degrees above the room temperature.
  3. A flame will appear in the display and the heat should turn on.
  4. Lower the temperature setpoint below the room temperature.
  5. The flame will disappear from the display and the heat should turn off.

Cooling (T8775C only)

CAUTION Low Temperature Hazard. Operating at too low of an outdoor temperature may cause compressor damage. Do not operate cooling if outdoor temperature is below 50°F (10°C). Refer to manufacturerís recommendations.

NOTE: If a call for cooling is made before the compressor has been off for five minutes, or if a power interruption occurs while the compressor is running, the thermostat will go into a five-minute delay to protect the compressor. The snowflake will flash during this delay.

  1. Slide the SYSTEM switch to Cool and the FAN switch to Auto.
  2. Lower the temperature setpoint several degrees below the room temperature.
  3. After approximately five minutes, the thermostat will display a solid snowflake and the cooling should turn on.
  4. Raise the temperature setpoint above the room temperature.
  5. The snowflake will disappear from the display and the cooling should turn off.

Fan

  1. Slide the SYSTEM switch to Off and the FAN switch to On. The fan should run continuously.
  2. Slide the FAN switch to Auto. The fan should turn off.

Automation and Control Solutions

OWNER’S GUIDE

Setting SYSTEM and FAN Switches (T8775C only)

IMPORTANT: Do not operate the T8775C in cooling mode when the outdoor temperature is below 50°F (10°C), or damage to compressor could result.

SET THE SYSTEM SWITCH:

SET THE FAN SWITCH:

Operating Your Thermostat

Display Temperature Setting

NOTE: Your temperature setting can be set anywhere from 40°F to 90°F (4°C to 32°C) in heating and 45°F to 99°F (7°C to 37°C) in cooling (T8775C only)

Adjust Temperature Setting

Troubleshooting Guide

CAUTION: Equipment Damage Hazard. Can cause permanent damage to compressor or other equipment. Do not operate cooling when outside temperature is below 50°F (10°C). Allow compressor to remain off for five minutes before restarting. See equipment manufacturer instructions

Heating or cooling does not come on.

Honeywell T8775A1009/U | File type: PDF | Filename: Honeywell T8775A1009:U The Digital Round® Non-Programmable Thermostat.pdf | Size: 378.46 KB | Language: English, Spanish | Other documents: 2 files.